Fitmore hip stem
WebCorrespondence: Bernd Alexander Ishaque, Department of Orthopaedics and Orthopaedic Surgery, University Hospital Giessen and Marburg (UKGM), Klinikstraße 33, Giessen, 35392, Germany, Tel +49 641 98542914, Fax +49 641 98542969, Email [email protected]. Abstract: Short stem hip replacement has … WebSep 29, 2024 · The subjects consisted of patients who underwent total hip arthroplasty (THA) with a Fitmore or GTS stem (both stems are manufactured by Zimmer Biomet Holdings, Inc., Indiana, USA) (Fig. 1) at Sapporo Medical University Hospital between April 2016 and March 2024.With regard to the stem used, patients were randomly selected by …
Fitmore hip stem
Did you know?
WebApr 1, 2014 · Fitmore ® Hip Stem is a curved uncemented stem with a trapezoidal cross-section, which is coated proximally with Ti-VPS (Titanium Vacuum Plasma Spray) and … WebMay 27, 2024 · Background An increased occurrence of cortical hypertrophy (CH) was observed 1–2 years after implanting short curved Fitmore hip stems. There are no …
Web18 yr old with L hip pain. What’s your go to stem for this? @freakhip 44 comments on LinkedIn WebSep 4, 2012 · Class 2 Device Recall Fitmore" Hip Stem: Date Initiated by Firm: September 04, 2012: Date Posted: November 06, 2012: Recall Status 1: Terminated 3 on April 16, …
WebThe Fitmore® hip stem (Zimmer, Warsaw, Ind) is a bone-conserving stem designed for use in MIS techniques. The technique described here is a single-incision anterior approach with the Fitmore system using a special orthopedic table. MeSH terms Arthroplasty, Replacement, Hip / methods* Hip Joint / diagnostic imaging ... WebOct 10, 2024 · Class 2 Device Recall FITMORE HIP STEM. All product manufactured prior to January 2014. Non-highly polished implants may adhere to the LDPE bag (previous packaging configuration). The firm distributed Urgent Medical Device Correction letters to customers on October 10, 2024. The letter informed customers that the previous version …
WebSep 23, 2024 · The Fitmore ® hip stem shows a high primary stability comparable to straight stem systems . The survival rate of the Fitmore ® hip stem after 8.6 years is reported with 99.6% (95% CI 97.1–99.9%) for the endpoint of “stem revision due to aseptic loosening”. However, the long-term impact of a low Canal Fill Index because of a high …
WebJan 25, 2024 · The Fitmore Hip Stem is a short and curved uncemented stem that allows preservation of the greater trochanter and of the gluteal muscles. Indication/Target … dewey defeats truman articleWebCurrently, an increasing number of younger patients undergo total hip arthroplasty surgery. This has led to a minimal invasive approach and the use of short, bone preserving, … dewey defeats truman original newspaperWebThe Zimmer femoral stems and necks are metal alloy implants used for hip replacements that allow the surgeon to fit the implant specifically to the patient. During hip replacement surgery, the damaged portions of the … church of the new founded by swedenborgWebDec 20, 2024 · Fitmore® hip stem is a titanium alloy stem (Ti Al6V4) that has a porolock Ti-VPS coating in the proximal part to enhance bone ingrowth and is available in four different neck angle options (127°, 129°, 137°, 140°) and 14 different sizes (size 1–14) for each offset option . A cementless titanium press-fit cup with or without screws ... dewey defeats truman bandWebThe Fitmore Hip Stem's short length and curved design helps preserve the patient's natural bone in the greater trochanter, where it matters most. Zimmer Biomet has been at the forefront of less invasive approaches to total hip arthroplasty. As the leader in Minimally Invasive Solutions™ procedures, Zimmer Biomet is proud to introduce the ... dewey defeats truman for saleWebJun 30, 2014 · Share on Social Media. Facebook. Twitter dewey defeats truman posterWebApr 18, 2011 · Fitmore® Hip Stem Manufacturing Process . HCP Content Posted April 18, 2011 in Manufacturing Videos church of the new testament